Skip to content
CleaningBrushes CleaningBrushes

Custom Cleaning Brush

Endotracheal Tube Brush

Endotracheal Tube Brush is built for bore, tube, and port where the brush must enter or follow internal walls, threads, and blind holes. Head size, working length, stem flexibility, and fill are selected to loosen chips, oil, and coolant without losing access or control.

Endotracheal Tube Brush cleaning brush
Made to OrderDimensions, fill, density and interface configured to the project
Brush TypeCustom Tube & Pipe Bore Brushes
ApplicationsCPAP Hose CleaningDental Tool CleaningLaboratory Tube CleaningMedical Instrument Cleaning
MaterialsPBTPolypropylene PPPA6 NylonPA612 Nylon

Product Features

Narrow head cleans respiratory tube interiors — Radial bristles reach the full inner wall.

Flexible stem follows curved tubes — The brush navigates the tube shape without excessive force.

Soft filament reduces surface damage — Fine nylon or suitable polymer cleans residue gently.

Protected tip limits scratching — Rounded or looped ends keep the wire core away from the tube wall.

Size and length matched to the tube — Brush diameter, head length, and stem reach can be identified for the intended tube dimensions.

Made to the tube — Diameter, working length, stem flexibility, filament, protected tip, handle, and packaging can be specified.

Product Overview

Endotracheal Tube Brush uses a working section shaped around the available opening, depth, and internal profile. It contacts internal walls, threads, and blind holes to remove chips, oil, and coolant; the access path and minimum clearance determine whether the brush needs a rigid stem, a flexible extension, a tapered head, or a stepped cleaning section. Brush diameter, working length, tip form, and stem flexibility must match the complete passage.

Key dimensions start with Brush head diameter 15–25 mm, Brush head length 40–100 mm, and Handle length 1200–2200 mm. The structure uses a tube or bore brush so the filament can contact the inside wall. The specified interface is threaded removable / fixed. PBT, Polypropylene PP, PA6 Nylon, and PA612 Nylon are the principal material directions in the current specification. Set the handle and head proportions around the working distance, access angle, and the level of contact control required.

Technical Specifications

Brush diameter15–25 mm
Working length40–100 mm
Overall length1200–2200 mm
Stem diameter1.0–3.0 mm
Filament diameter0.08–0.25 mm
Handle or loop20–60 mm
Contact settingUse near-size contact for wiping and 5–20% oversize for flexible polymer scrubbing; use lower interference with wire.
Fill materialsPBT, Polypropylene PP, PA6 Nylon, and PA612 Nylon
Cleaning zonebore, tube, port, and internal-passage cleaning
Contact surfaceinternal walls, threads, blind holes, cross holes, tapers, ports, and curved passages
Residue classchips, oil, coolant, scale
Access and motionbrush diameter, working length, tip form, and stem flexibility must match the complete passage
Cleaning dutybore, tube, port on internal walls, threads, blind holes, cross holes
Variant configurationEndotracheal Tube Brush: tube, flexible spring construction with PBT, Polypropylene PP, PA6 Nylon, PA612 Nylon fill for bore, tube, port, and internal-passage cleaning on internal walls, threads, blind holes, cross holes.

Application Areas

Endotracheal Tube Brush is primarily mapped to CPAP Hose Cleaning. If the brush will be used on a different job, confirm the surface, debris discharge path, and acceptable finish first.

  • Endotracheal Tube Brush is best suited to CPAP hose, breathing tube, mask tube, and respiratory hose cleaning.
  • The twisted-in-wire, flexible-rod, pull-through, fan-tip, or powered bore brush follows corrugated hose interior, smooth tube wall, connector, elbow, and mask passage while the fill displaces condensation film, lint, dust, soap residue, and biofilm.
  • Use this configuration when the available access supports radial filament contact inside a bore, tube, hose, channel, nozzle, or drilled passage.

Selection Guidance

Structure fit

Match the tube & pipe bore brush geometry to internal walls, threads, and blind holes, the available access, and manual operation. Confirm Brush head diameter 15–25 mm, Brush head length 40–100 mm, and Handle length 1200–2200 mm against the complete working envelope before finalizing the brush.

Contact material

Choose from PBT, Polypropylene PP, PA6 Nylon, and PA612 Nylon according to the behavior of chips, oil, and coolant, the surface sensitivity, and any wet, chemical, temperature, or hygiene requirements. The same material can feel very different depending on filament diameter, free trim, and fill density.

When to use another solution

For Endotracheal Tube Brush, use another cleaning method when chips, oil, and coolant cannot be released by controlled filament contact, when internal walls, threads, and blind holes cannot tolerate the selected contact material, or when the access path prevents safe engagement and residue removal.

Customization Options

Brush Head Diameter (mm)15–25
Brush Head Length (mm)40–100
Handle Length (mm)1200–2200
Handle Grip Diameter (mm)Not Applicable (No explicit grip or handle-diameter dimension in the product specification)
Bristle MaterialPBT, Polypropylene PP, PA6 Nylon, PA612 Nylon
Handle Material304 Stainless Steel
Mounting / InterfaceThreaded Removable / Fixed
Grip StyleStraight Handle
ColorCustom PANTONE Color ([Industry Reference Range])
Logo ProcessLaser Engraving / Screen Printing / Pad Printing ([Industry Reference Range])
Surface TreatmentSmooth / Textured / Overmolded / Coated (Depending on Substrate; [Industry Reference Range])

Frequently Asked Questions

How should Endotracheal Tube Brush be selected?

Start with CPAP hose, breathing tube, mask tube, and respiratory hose cleaning, corrugated hose interior, smooth tube wall, connector, elbow, and mask passage, and condensation film, lint, dust, soap residue, and biofilm. Then set Brush diameter, Working length, and Overall length, choose the fill from the material and residue table, and match the mounting interface and operating condition.

Which dimensions define Endotracheal Tube Brush?

The primary dimensions are Brush diameter (15–25 mm), Working length (40–100 mm), and Overall length (1200–2200 mm). Also provide the minimum clearance, working envelope, trim or engagement, and the existing holder, shaft, stem, thread, or handle.

Which filament or contact material is used for Endotracheal Tube Brush?

The primary options are PBT, Polypropylene PP, PA6 Nylon, and PA612 Nylon. The final choice follows surface sensitivity, residue adhesion, wet or dry use, temperature, chemicals, conductivity, and required cutting action.

When is Endotracheal Tube Brush not the best cleaning method?

Endotracheal Tube Brush is not the first choice for pigs, flushing, ultrasonic, chemical descaling, blasting, or a flexible cable system for long, sharply curved, or heavily scaled passages.

What information is required to quote Endotracheal Tube Brush?

Send the part or machine drawing, photos of corrugated hose interior, smooth tube wall, connector, elbow, and mask passage, Brush diameter, Working length, Overall length, and Stem diameter, the residue description, wet or dry conditions, motion or use method, temperature, preferred PBT, Polypropylene PP, PA6 Nylon, and PA612 Nylon, quantity, and the existing interface or sample.

Custom Manufacturing RFQ

Upload the Brush Drawing, Product Photo or Sample Details

Please include the main sizes, application, residue, preferred material, interface, quantity, and any drawing or sample available.

JPG / PNG / WEBPPDFSTEP / STPDXF / DWGIGS / IGESZIP

Custom Brush RFQ

Send Your Brush Project

Upload a drawing, product photo, or sample photo and provide the core dimensions and cleaning conditions.

Advanced brush dimensions and construction
Chat on WhatsApp

Need Custom Help?

Choose your brush type, cleaning task, material direction, and key details before sending a custom brush request.

Brush shortcut
WhatsApp